Molecular Devices · Electrofisiología
Axoclamp 900A
Instrumento de electrofisiología de Molecular Devices.
1–2000 in 1:2:5 sequence
Scaled output Gain
Single-pole; DC-300 Hz
Highpass filter
4-pole Bessel, 2 Hz to 30 kHz; Butterworth, 3 Hz to 45 kHz
Lowpass filter

Axoclamp 900A es un(a) instrumento de electrofisiología de Molecular Devices, orientado a registro de canales iónicos y patch clamp.
Aplicaciones ideales
- Registro de canales iónicos
- Patch clamp
- Estudios de membrana celular
Especificaciones
- Scaled output Gain
- 1–2000 in 1:2:5 sequence
- Highpass filter
- Single-pole; DC-300 Hz
- Lowpass filter
- 4-pole Bessel, 2 Hz to 30 kHz; Butterworth, 3 Hz to 45 kHz
- Output (DC) offset
- ±3 V
- Current output
- 1 per channel
- Current output Gain
- 10, 100, or 1000 nA/V
- Auxiliary headstage
- 1 per channel, gain 10 V/V
- Pipette offset
- ±250 mV
- Pipette capacitance neutralization
- -10 to 35.5 pF
- Buzz
- Increases capacitance 4 pF for duration of 0.1–500 ms
- Clear (±)
- Maximum positive or negative current—duration up to 0.5 sec
- Cumplimiento normativo
- ±180 V
- Cumplimiento normativo
- ±12 V
- Step activate
- Independent on channels 1 & 2, internal or external timing up to 50 kHz
- I-CLAMP Internal holding level max.
- ±10 nA, ±100 nA, or ±1000 nA
- Sensibilidad
- 1, 10, or 100 nA/V
- DCC Internal holding level max.
- ±10 nA, ±100 nA, or ±1000 nA
- Sensibilidad
- 1, 10, or 100 nA/V
- HVIC Internal holding level max.
- ±0.13, +1.3, or 13.0 μA
- Sensibilidad
- 10, 100, or 1000 nA/V
- DSEVC Internal holding level
- ±200 mV
- Voltaje
- 0.003–30 nA/mV, 0.03–300 nA/mV, or 0.3–3000 nA/mV
- Sensibilidad
- 20 mV/V
- Voltaje
- 250 μs
- DSEVC Current settling time
- 500 μs to 10% of peak value
- Nivel de ruido
- 180 μV rms
- Nivel de ruido
- 0.30 nA rms
- TEVC Internal holding level
- ±200 mV
- Voltaje
- 20 to 50,000
- Voltaje
- 5.4 μs–52 ms
- Sensibilidad
- 20 mV/V
- Voltaje
- 60 μs
- TEVC Current settling time
- 80 μs to 10% of peak value
- Nivel de ruido
- 23 μV rms
- Nivel de ruido
- 70 nA rms
- Dimensiones
- 4.3 (H) x 19 (W) x 14.3 (D)
- Dimensiones
- 10.9 (H) x 48.3 (W) x 36.3 (D)
- Peso
- 9.5 lbs
- Peso
- 4.3 kg
- Headstage (in.)
- 0.75 (H) x 0.70 (W) x 2.25 (D)
- Headstage (cm)
- 1.9 (H) x 1.8 (W) x 5.7 (D)
- Communications
- (3) USB 2.0 Type B female ports
- Rack use
- Standard 19" rack-mount (2U) with handles
- Potencia
- 100–240 Vac 50–60 Hz, 30 watts (max.)
- Safety
- CE marking (Conformité Européan)
- Computer
- 1 GHz or better processor, Windows 2000/XP, CD-ROM drive 512 MB RAM, 500 MB HD space
Cumplimiento
CE marking
Industrias
InvestigaciónNeurocienciaFarmacología
Equipos relacionados
¿Te interesa el Axoclamp 900A?
Cuéntanos tu aplicación y un especialista de Inolab te ayuda con la configuración y la cotización.
Hablar con un especialista